Sign In | Join Free | My chinacsw.com |
|
Brand Name : Daxian
Model Number : DX8534
Certification : GB/T 1633-2000
Place of Origin : China
MOQ : One set
Price : Negotiation
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Supply Ability : 15 sets per month
Delivery Time : 15 work days
Packaging Details : Wooden Case
Standard : GB/T 1633-2000,GB/T 1634.1-2004,GB/T 1634.2-2004
Scope of application : Mainly used for the determination of thermal deformation and Vicat softening point temperature of polymer materials
Test range : room temperature~300 ℃
Heater power : 4KW
Main power supply : 220V+10%, 15A, 50HZ
Heating rate : A=5℃/6min B=12℃/6min
DX8534 Thermal Deformation and Vicat Softening Point Temperature Tester (Micro Control)
Applicable scope:
Mainly used for the determination of thermal deformation and Vicat softening point temperature of polymer materials (such as plastics, rubber, nylon, electrical insulation materials, etc.). Applicable to universities and colleges, research institutions, and product quality supervision and inspection units.
Compliant with standards:
Complies with the requirements of GB/T 8802-2001, ISO 2570 rigid polyethylene (PVC), GB/T 1633, GB/T 1634, ISO 75-1987 (E), ISO 306-1987 (E) and other standards.
Compliant with standards:
GB/T 1633-2000 (idt ISO 306:1994) Determination of Vicat Softening Temperature (VST)
GB/T 1634.1-2004 (idt ISO75-2:2003) Plastics Determination of Load Deformation Temperature (General Test Method)
GB/T 1634.2-2004 Plastics Determination of Load Deformation Temperature (Plastics, Hard Rubber, and Long Fiber Reinforced Composite Materials)
GB/T 1634.3-2004 Plastics Determination of Load Deformation Temperature (High Strength Thermosetting Laminated Materials)
GB/T 8802-2001 (eqv ISO 2507:1995) Thermoplastic pipes and fittings - Determination of Vicat softening temperature
Main performance indicators:
Test range: room temperature~300 ℃;
Number of sample racks: 2, 3, and 6;
Heater power: 4KW;
Vicat Disturbance: 1mm.
Deformation resolution error: 0.005mm
Heating rate: A=5℃/6min B=12℃/6min;
Maximum temperature measurement error: ± 0.5 ℃
Maximum temperature control error: ± 12 ℃/6 minutes (hot deformation test) ± 5 ℃/6 minutes (Vicat test)
Weight of weights(i.e. load rod, standard indenter, Sensor probe, tray, screw): 68g±1g
Heating medium: silicone oil (below 200 millimeters, flash point above 300 ℃)
Cooling method: natural cooling or water cooling (C-type machine)
External dimensions: 520×four hundred and twenty×1100mm;
Main power supply: 220V+10%, 15A, 50HZ;
A set of experimental application software for the Chinese version of the operating system of the thermal deformation and Vicat softening point temperature tester
![]() |
DX8534 Thermal Deformation And Vicat Softening Point Temperature Tester Micro Control Images |